STANDARD FEATURES
- 1 1/4” Insulated glass
- Factory glazed for site ease
- Modular design allows for various operable infills
- Strutted design for superior thermal performance
- Full receptor system for easy site installation
- Slim sightlines
- Male / female jambs for easy field stacking
- Versatile for both punched and wall requirements
- Cantilevered off the edge of the slab for bypass
capabilities - Integrated slab cover
- Dedicated and captured 90° corners
OPTIONAL FEATURES
- Shadowbox, UHPC, Panel or Spandrel infills
- Operable Vent and Door plug-in options
- Reinforcement for larger spans
- Glazing up to 1 3/8” to meet higher OITC values
- Glazing options to meet 2020 EEC C401 U-Value and
- SHGC requirements for fixed curtain wall
AVAILABLE ACCESSORIES
- Slab edge insulation
- Intermittent stabilization anchors
- Window washer bolts
- Parapet covers
- Deco caps or fins
- Trickle vents
Type | AAMA Rating | STRUCTURAL LOAD (psf) | TEST SIZE | WIND SPEED (mph) | AIR (cfm/ft²) | WATER (psf) | U-VALUE¹ |
---|---|---|---|---|---|---|---|
Fixed | AW-100 | 150 | 60" x 99" | 50 (6.24 psf) | <0.1 | 15 | 0.38 |
* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.
STANDARD FEATURES
- 1 1/4” Insulated glass
- Factory glazed for site ease
- Modular design allows for various operable infills
- Strutted design for superior thermal performance
- Full receptor system for easy site installation
- Slim sightlines
- Male / female jambs for easy field stacking
- Versatile for both punched and wall requirements
- Cantilevered off the edge of the slab for bypass
capabilities - Integrated slab cover
- Dedicated and captured 90° corners
OPTIONAL FEATURES
- Shadowbox, UHPC, Panel or Spandrel infills
- Operable Vent and Door plug-in options
- Reinforcement for larger spans
- Glazing up to 1 3/8” to meet higher OITC values
- Glazing options to meet 2020 EEC C401 U-Value and
- SHGC requirements for fixed curtain wall
AVAILABLE ACCESSORIES
- Slab edge insulation
- Intermittent stabilization anchors
- Window washer bolts
- Parapet covers
- Deco caps or fins
- Trickle vents
Type | AAMA Rating | STRUCTURAL LOAD (psf) | TEST SIZE | WIND SPEED (mph) | AIR (cfm/ft²) | WATER (psf) | U-VALUE¹ |
---|---|---|---|---|---|---|---|
Fixed | AW-100 | 150 | 60" x 99" | 50 (6.24 psf) | <0.1 | 15 | 0.38 |
* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.