STANDARD FEATURES
- 1” Structurally glazed insulated glass
- Euro-groove design for hardware versatility
- Triple gasket design
- Hidden sash with matching fixed lite
- Polyamide strut for superior thermal performance
- Dual finish, 2-tone option
- 4” Limit stop
- Multi-point locking hardware for added security
- Fixed and operable in single masterframe
- Thermally broken sash
- Dual finish or 2-tone option
- Unique “edge guard” protection
- 1 ⅛” glazing
- Dual action tilt and turn hardware
- Custodial lock
- Applied Flange (1”, 1 ½”, 2½”, 3 ¼”)
- Trims
- Receptor with subsill
MODEL | AAMA RATING | STRUCTURAL LOAD (psf) | TEST SIZE | WIND SPEED | AIR (cfm/ft²) | WATER | U-VALUE¹ |
---|---|---|---|---|---|---|---|
Inswing | AW-80 / 100 / 120 | 120 / 150 / 180 | 36” x 60” | 50 (6.24psf) | <0.1 | 12 - 15 | 0.38 - 0.45 |
Dual Action | AW-70 / 90 / 130* | 105 / 135 / 195 | 60” x 99” | 50 (6.24psf) | <0.1 | 12 - 18 | 0.38 - 0.45 |
* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.
STANDARD FEATURES
- 1” Structurally glazed insulated glass
- Euro-groove design for hardware versatility
- Triple gasket design
- Hidden sash with matching fixed lite
- Polyamide strut for superior thermal performance
- Dual finish, 2-tone option
- 4” Limit stop
- Multi-point locking hardware for added security
OPTIONAL FEATURES
- Fixed and operable in single masterframe
- Thermally broken sash
- Dual finish or 2-tone option
- Unique “edge guard” protection
- 1 ⅛” glazing
- Dual action tilt and turn hardware
- Custodial lock
AVAILABLE ACCESSORIES
- Applied Flange (1”, 1 ½”, 2½”, 3 ¼”)
- Trims
- Receptor with subsill
MODEL | AAMA RATING | STRUCTURAL LOAD (psf) | TEST SIZE | WIND SPEED | AIR (cfm/ft²) | WATER | U-VALUE¹ |
---|---|---|---|---|---|---|---|
Inswing | AW-80 / 100 / 120 | 120 / 150 / 180 | 36” x 60” | 50 (6.24psf) | <0.1 | 12 - 15 | 0.38 - 0.45 |
Dual Action | AW-70 / 90 / 130* | 105 / 135 / 195 | 60” x 99” | 50 (6.24psf) | <0.1 | 12 - 18 | 0.38 - 0.45 |
* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.