PW-202 Curtain Wall

With a 2” face dimension to match Northern storefront profiles the PW-202 pressure wall is perfect for low to midrise application such as Clerestory. The PW-202’s screw spline split mullion design is perfect for bridging the gap between the 451T storefront and the PW-252 wall.

STANDARD FEATURES

  • Outside glazed captured Curtain Wall
  • 2” sight line
  • 4 1/2” system depth
  • Concealed Fastener Joinery creates smooth, monolithic appearance
  • Screw spline fabrication
  • Bronze or Clear Anodized finish

OPTIONAL FEATURES

  • Corners and Splayed Mullions
  • Integrated entrance framing systems
  • Silicone-compatible glazing materials, including structural glazing
  • Dual Finish or paint
  • Steel reinforcement

AVAILABLE ACCESSORIES

  • Standard F and T anchors

STRUCTURAL LOAD (psf)TEST SIZEWIND SPEED (mph)STATIC AIR (cfm/ft²)DYNAMIC AIR (cfm/ft²)STATIC WATER (psf)DYNAMIC AIR (psf)
22.5155.5" x 256.75"50 (6.24psf)0.010.011515

* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.

Download all

STANDARD FEATURES

  • Outside glazed captured Curtain Wall
  • 2” sight line
  • 4 1/2” system depth
  • Concealed Fastener Joinery creates smooth, monolithic appearance
  • Screw spline fabrication
  • Bronze or Clear Anodized finish

OPTIONAL FEATURES

  • Corners and Splayed Mullions
  • Integrated entrance framing systems
  • Silicone-compatible glazing materials, including structural glazing
  • Dual Finish or paint
  • Steel reinforcement

AVAILABLE ACCESSORIES

  • Standard F and T anchors

STRUCTURAL LOAD (psf)TEST SIZEWIND SPEED (mph)STATIC AIR (cfm/ft²)DYNAMIC AIR (cfm/ft²)STATIC WATER (psf)DYNAMIC AIR (psf)
22.5155.5" x 256.75"50 (6.24psf)0.010.011515

* Down-sized testing
Performance data based on testing by AAMA Accredited Laboratory and NFRC Simulation software/or independent testing. Actual results will vary based on field conditions, locations, size/configurations or glazing options. Be sure to verify the performance requirements for your particular project. 1 U-Values will vary depending on the glazing selected. Please contact Northern for more information.